Most of the leakages of newly installed mechanical seals comes from the improper installation.
-
The designed face pressure rate is not accurate to meet the requirements.
-
The inaccuracy of the amount of spring compression
-
The seal surface roughness does not meet the standard
-
The seal face flatness does not meet the standard.
-
The seal rings distort due to the pressure and temperature. It damages the flatness of the mechanical seal faces
-
The Seizure of rotary and rotary holder.
-
Rotary and seat is not concentric.
-
The Load factor of balanced mechanical seals is not accurate (always too small)
-
The OD and ID of the metal bellow are inaccurate.